Distribution transformer 50 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 100 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 160 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 200 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 250 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 315 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 400 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 500 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 630 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 800 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 1000 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 1250 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 1600 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 2000 kVA, 11kV/0.4kV, ONAN, copper wound

Distribution transformer 2500 kVA, 11kV/0.4kV, ONAN, copper wound

Power transformer 2000 kVA, 33kV/11kV, ONAN/ONAF, OLTC

Power transformer 3150 kVA, 33kV/11kV, ONAN/ONAF, OLTC

Power transformer 5000 kVA, 33kV/11kV, ONAN/ONAF, OLTC

Power transformer 7500 kVA, 33kV/11kV, ONAN/ONAF, OLTC

Power transformer 10000 kVA, 33kV/11kV, ONAN/ONAF, OLTC

Power transformer 16000 kVA, 33kV/11kV, ONAN/ONAF, OLTC

Power transformer 20000 kVA, 33kV/11kV, ONAN/ONAF, OLTC

Power transformer 31500 kVA, 33kV/11kV, ONAN/ONAF, OLTC

Cast resin dry-type transformer 1000 kVA, 11kV/0.4kV

Furnace transformer 6-12 MVA for induction/arc furnace



Transformers: buying guide and questions
How to choose a transformer
- Rating
- Size the kVA from the total connected load, the diversity factor and future expansion; typical factory sizes are 250–2500 kVA.
- Voltage
- 11 kV primary to 0.4 kV (415 V) secondary is standard in Bangladesh; 33 kV primaries for larger sites.
- Type
- Oil-immersed ONAN for outdoor sub-stations (lower cost, high overload capacity); cast resin dry-type for indoor and fire-sensitive locations.
- Losses
- Compare no-load and load losses: a low-loss transformer costs more but saves energy over its 25+ year life.
- Tests and standards
- IEC 60076 / BDS IEC; routine test reports, and type tests or BPDB/DESCO/DPDC approval where the utility requires it.
What is the price of a 500 kVA transformer in Bangladesh?
Transformer prices depend on rating, oil or dry type, winding material (copper or aluminium), losses and brand, and copper price changes. Send the kVA, voltage ratio, type and quantity and we quote within 24 hours.
Oil-immersed or dry-type transformer?
Oil-immersed transformers are cheaper and suit outdoor sub-stations; dry-type cast resin transformers need no oil, so they are preferred indoors and in buildings where fire safety matters.
Do you supply complete sub-stations?
Yes: HT switchgear, transformer, LT panel and power-factor improvement plant can be supplied together. Brands we list: ABB, Siemens, Energypac, ETL, Transtec, Hyundai, Schneider and Trafo.