Cast resin dry-type transformer 1000 kVA, 11kV/0.4kV
Pricing depends on specification, quantity and delivery location. Send your requirement and we reply with a costed quotation within 24 hours.
Quick overview
- Type: Transformer
- Rating (kVA): 1000
- Voltage: 11kV/0.4kV
- Cooling: Dry-type
- Genuine productsSourced from the manufacturer or authorised channels
- Delivery across BangladeshDhaka, Chattogram and all industrial zones
- After-sales supportInstallation guidance and warranty handling
- Reply within 24 hoursCall +880 1713 552466 or email hello@argonmark.com
Specifications
| General | |
|---|---|
| Part no. | BD-0025 |
| Category | Electrical — Power & Distribution |
| Group | Electrical |
| Brand | ABB |
| Available / equivalent brands | ABB, Schneider, Trafo |
| Technical | |
| Type | Transformer |
| Rating (kVA) | 1000 |
| Voltage | 11kV/0.4kV |
| Cooling | Dry-type |
Datasheet
Design standard
| Dry-type transformers | IEC 60076-11 |
|---|---|
| Power transformers | IEC 60076-1 |
Technical features
| Windings encapsulated in epoxy resin under vacuum: no oil, low fire risk | |
| For indoor substations in buildings, hospitals, factories and high-rise projects | |
| Natural (AN) cooling with optional fans (AF) for up to about 40 % extra rating | |
| Winding temperature monitoring with PT100 sensors and relay |
Typical specification (product type)
| Rating | 250 – 3150 kVA |
|---|---|
| Voltage | 11 / 0.415 kV (33 kV on request) |
| Vector group | Dyn11 |
| Cooling | AN / AF |
| Insulation class | F (155 °C) |
| Impedance | ≈ 4 – 6 % |
| Enclosure | IP00 or IP21 / IP31 enclosure |
Notes
| Climatic, environmental and fire classes (C2 / E2 / F1) on request. | |
| Typical values for this product type; the exact rating, size and materials are confirmed in Argonmark's quotation for the selected make and model. |
Photo: unknown, CC BY 3.0, via Wikimedia Commons — illustrative photo of the product type, edited by Argonmark. All photo credits
Description
Cast-resin dry-type transformer. Windings encapsulated in epoxy resin under vacuum: no oil, low fire risk. For indoor substations in buildings, hospitals, factories and high-rise projects. Natural (AN) cooling with optional fans (AF) for up to about 40 % extra rating.
Argonmark Ltd supplies this item to factories, power plants, utilities, contractors and government projects across Bangladesh. Send us the required size, rating, materials and quantity and we will reply with a quotation within 24 hours.