Steam condensate recovery system (LPMP pumps)
Pricing depends on specification, quantity and delivery location. Send your requirement and we reply with a costed quotation within 24 hours.
Quick overview
- Type: Boiler & Steam
- Models: HPT10, HP10, HPT30, HP30
- Configuration: Single or double pump system (pumps in parallel)
- Motive medium: Steam or compressed air
- Pump inlet / outlet: DN80 × DN50
- Connection: RF DIN PN16 (DN80); Sc 1/2" (DN15)
- Genuine productsSourced from the manufacturer or authorised channels
- Delivery across BangladeshDhaka, Chattogram and all industrial zones
- After-sales supportInstallation guidance and warranty handling
- Reply within 24 hoursCall +880 1713 552466 or email hello@argonmark.com
Specifications
| General | |
|---|---|
| Part no. | BD-1239 |
| Category | Boilers, Steam & Heat Transfer |
| Group | Heating, Cooling & HVAC |
| Brand | Argonmark |
| Technical | |
| Type | Boiler & Steam |
| Models | HPT10, HP10, HPT30, HP30 |
| Configuration | Single or double pump system (pumps in parallel) |
| Motive medium | Steam or compressed air |
| Pump inlet / outlet | DN80 × DN50 |
| Connection | RF DIN PN16 (DN80); Sc 1/2" (DN15) |
| Pressure rating | Test pressure 13.8 MPa |
| Working temperature | ≤ 180°C |
Datasheet
Design standard
| Design & manufacture | JB/T 11170-2011 |
|---|---|
| Discharges 25 kg of condensate at each working cycle | |
| Weld seam thickness more than 6 mm at each welding position | |
Technical features
| Self-contained pumps driven by steam or other pressurised gas; recover condensate (or other fluids) under all operating conditions | |
| Suitable for hazardous areas where electrical pumps are not, and for efficient drainage of heat exchangers | |
| Recovering condensate improves production efficiency, reduces water-treatment cost and uses steam fully | |
| Eliminates water hammer, avoiding equipment damage and improving reliability and safety | |
| Reduces boiler fuel cost and down-stream water treatment and drainage | |
| Recovers condensate up to 185°C without evaporation | |
| Selection | check max. flow rate, the motive medium's pressure and temperature, and total back pressure (vertical lift, condensate line pressure, pipe/valve/fitting losses) |
|---|---|
| Motive pressure supplied by the customer must be 0.1–0.15 MPa higher than the total back pressure | |
Main performance specification
| Test pressure | 13.8 MPa |
|---|---|
| Shell test | 4.0 MPa, 10 min |
| Seal test | 0.6 MPa, 5 min |
| Working test | More than 200 times |
| Suitable temperature | ≤ 180°C |
| Unit body seal | 0.6 MPa, 10 min |
| Tank test (closed system) | 2.5 MPa, 5 min |
Main parts materials
| No. | Part | Material |
|---|---|---|
| 1 | Set water tank | Assembly |
| 2 | Inlet assembly | Assembly |
| 3 | Pump body | WCB |
| 4 | Trim | SS |
| 5 | Outlet assembly | Assembly |
| 6 | Driving air pipe | Assembly |
| 7 | Air vent pipe | Assembly |
| 8 | Gasket | Graphite + SS |
| 9 | Drain plug | 45# |
| 10 | Studs | 8.8 |
Quantity 1 of each part.
Main dimensions (mm)
| Type | L | W | H |
|---|---|---|---|
| Single pump system assembly | 1150 | 750 | 1670 |
| Double pump system assembly | 1170 | 1150 | 1760 |
Pump body dimensions (mm)
| Type | A | B | C | D |
|---|---|---|---|---|
| Pump body | 340 | 540 | 540 | 130 |
Connections
| Code | Name | Size | Connection |
|---|---|---|---|
| a | Inlet | DN80 | RF DIN PN16 |
| b | Air vent | DN80 | RF DIN PN16 |
| c | Overflow | DN80 | RF DIN PN16 |
| d | Driving air | DN15 | Sc 1/2" |
| e | Drain | DN15 | Sc 1/2" |
Selection: back pressure / driving pressure factor
| Back / driving pressure | 10% | 20% | 30% | 40% | 50% | 60% | 70% | 80% | 90% |
|---|---|---|---|---|---|---|---|---|---|
| Pump inlet size factor | 1.04 | 1.06 | 1.08 | 1.10 | 1.12 | 1.15 | 1.18 | 1.23 | 1.28 |
Capacity, pump DN80 × DN50
| Driving pressure | Back pressure | Single pump | Double pump |
|---|---|---|---|
| 2 | 1.0 | 4050 | 8100 |
| 4 | 1.0 | 6020 | 12040 |
| 4 | 2.0 | 4100 | 8200 |
| 4 | 3.0 | 2160 | 4320 |
| 5 | 1.0 | 6730 | 13460 |
| 5 | 2.0 | 4770 | 9540 |
| 5 | 3.0 | 3330 | 6660 |
| 5 | 4.0 | 1900 | 3800 |
| 7 | 2.0 | 5580 | 11160 |
| 7 | 3.0 | 4410 | 6620 |
| 7 | 4.0 | 3780 | 7560 |
| 7 | 5.0 | 3150 | 6300 |
| 9.5 | 3.0 | 6480 | 12960 |
| 9.5 | 4.0 | 5670 | 11340 |
| 9.5 | 5.0 | 4680 | 9360 |
| 9.5 | 6.0 | 3690 | 7380 |
| 9.5 | 7.0 | 3060 | 3120 |
| 12 | 4.0 | 6390 | 12780 |
| 12 | 5.0 | 5580 | 11160 |
| 12 | 6.0 | 4410 | 8820 |
| 12 | 7.0 | 3760 | 7560 |
| 12 | 8.0 | 3150 | 6300 |
| 13.8 | 5.0 | 6120 | 12240 |
| 13.8 | 6.0 | 4950 | 9900 |
| 13.8 | 7.0 | 4230 | 5460 |
| 13.8 | 8.0 | 3690 | 7360 |
| 13.8 | 9.0 | 3420 | 6640 |
Values as printed on the supplier's select datasheet. Units are not stated in the table; the order form uses bar for pressures and kg/h for condensate.
Notes
| Order requirements | driving medium (compressed air or saturated steam), driving pressure (bar), back pressure (bar), condensate (kg/h). |
|---|
Description
Steam condensate recovery system. Collects hot condensate and pumps it back to the boiler. Saves water, fuel and treatment chemicals.
Argonmark Ltd supplies this item to factories, power plants, utilities, contractors and government projects across Bangladesh. Send us the required size, rating, materials and quantity and we will reply with a quotation within 24 hours.
Questions & answers
Customer questions
No questions asked yet. Ask about specification, compatibility, lead time or anything else about this item.
Reviews