Isotech Calisto 4953 multifunction temperature calibrator (dry block / liquid bath), 30 to 250 °C
Pricing depends on specification, quantity and delivery location. Send your requirement and we reply with a costed quotation within 24 hours.
Quick overview
- Type: Calibration equipment
- Signal / Protocol: USB
- Hazardous area: General purpose
- Genuine productsSourced from the manufacturer or authorised channels
- Delivery across BangladeshDhaka, Chattogram and all industrial zones
- After-sales supportInstallation guidance and warranty handling
- Reply within 24 hoursCall +880 1713 552466 or email hello@argonmark.com
Specifications
| General | |
|---|---|
| Part no. | BD-1437 |
| Category | Oil & Gas Instruments |
| Group | Instrumentation & Control |
| Brand | Isotech |
| Model | Calisto 4953 (Isocal-6) |
| Technical | |
| Type | Calibration equipment |
| Signal / Protocol | USB |
| Hazardous area | General purpose |
Datasheet
Technical features
| Six modes | dry block, stirred liquid bath, surface sensor, infrared blackbody and ITS-90 fixed point accessories |
|---|---|
| Calibrates the whole measurement loop | |
| Advanced version | inputs for reference and test thermometers, automatic cycling, secure data logging, web server, colour display |
| Site version | built-in independent indicator for a reference probe |
| Meets EURAMET cg-13 calibration capacity requirements; I-Cal Easy LOG software included | |
Applications
| Calibration of RTDs, thermocouples, thermometers and temperature loops | |
| Surface and infrared thermometer checks with accessories |
General
| Calibration volume | 35 mm × 160 mm |
|---|---|
| Standard insert | 6 pockets: 2 × 4.5, 2 × 6.4, 1 × 8.0, 1 × 9.5 mm, all 157 mm deep |
| Dimensions | 384 H × 212 W × 312 D mm |
| Power | 300 W, 115 or 230 V AC 50/60 Hz |
| Weight | 8 kg |
Key specifications
| Temperature range | 30 to 250 °C (in 20 °C ambient) |
|---|---|
| Stability | ±0.03 °C (Basic/Site); ±0.02 °C (Advanced) |
| Display accuracy | 0.25 °C (dry block, 4.5 mm well) |
| Calibration volume | 35 × 160 mm, 6-pocket standard insert |
| Versions | Basic, Site (reference indicator), Advanced (logging, cycling) |
| Power | 300 W, 115 or 230 V AC |
Performance
| Temperature range | 30 to 250 °C (20 °C ambient) |
|---|---|
| Stability (Advanced) | ±0.02 °C dry block / liquid bath |
| Stability (Basic/Site) | ±0.03 °C |
| Display resolution | 0.01 °C |
| Display accuracy | 0.25 °C (dry block mode) |
| Uniformity between wells (dry block) | < 0.02 °C at 250 °C |
| Axial uniformity, lower 40 mm | < 0.25 °C dry block; < 0.02 °C liquid bath at 250 °C |
| Heating / cooling | 25 → 250 °C in 15 min; 250 → 30 °C in 25 min |
| Other modes | Blackbody ±0.3 °C; surface sensor ±0.5 °C; ITS-90 cells ±0.0005 °C |
Advanced input channels
| RTD input | ±0.005% of reading |
|---|---|
| Thermocouple input | E, J, K, N ±0.2 °C at 660 °C; R ±0.6 °C; S ±0.7 °C; T ±0.2 °C at 150 °C |
| CJC accuracy | ±0.35 °C |
| Interface | Ethernet + USB host (Basic/Site: serial) |
Notes
| Data from the manufacturer's published datasheet. Confirm model, range, materials and approvals with Argonmark before ordering. |
Photo: courtesy of Isotech, used with permission (source) — background removed by Argonmark. All photo credits
Description
The Isotech Calisto 4953 is a multifunction temperature calibrator for 30 °C to 250 °C that works as a dry block or, with accessories, as a stirred liquid bath, surface-sensor calibrator, infrared blackbody or ITS-90 fixed-point system. Its 35 × 160 mm calibration volume takes a six-pocket insert, with stability of ±0.03 °C (±0.02 °C in the Advanced version).
The Basic version shows set and block temperature, the Site adds a reference-probe indicator, and the Advanced adds test-thermometer inputs, automatic cycling and secure data logging, so a whole measurement loop can be calibrated in the field.
Argonmark Ltd supplies Isotech instruments across Bangladesh — Dhaka, Chattogram, Gazipur, Narayanganj and the gas fields, refineries, terminals and power plants beyond. Send us the model, range, process connection, output and any hazardous-area requirement, and we will confirm the right configuration, lead time and price.
Questions & answers
Customer questions
No questions asked yet. Ask about specification, compatibility, lead time or anything else about this item.
Reviews
No reviews yet. Bought or used this item? Be the first to share your experience.