Isotech Fast-Cal industrial dry block calibrator, −35 to 650 °C (Low, Medium, High, HTM 2010)
Pricing depends on specification, quantity and delivery location. Send your requirement and we reply with a costed quotation within 24 hours.
Quick overview
- Type: Calibration equipment
- Hazardous area: General purpose
- Genuine productsSourced from the manufacturer or authorised channels
- Delivery across BangladeshDhaka, Chattogram and all industrial zones
- After-sales supportInstallation guidance and warranty handling
- Reply within 24 hoursCall +880 1713 552466 or email hello@argonmark.com
Specifications
| General | |
|---|---|
| Part no. | BD-1439 |
| Category | Oil & Gas Instruments |
| Group | Instrumentation & Control |
| Brand | Isotech |
| Model | Fast-Cal |
| Technical | |
| Type | Calibration equipment |
| Hazardous area | General purpose |
Datasheet
Technical features
| Rugged, hygienic stainless steel case with no paint and no membrane keypad | |
| Lightweight (under 6.6 kg) and easy to carry on site; carrying case included | |
| Basic (compare to controller) or Complete (built-in indicator + semi-standard probe for traceable ISO 9000 calibration) versions | |
| Complete model captures thermostat trip temperatures; 4–20 mA input | |
| HTM 2010 fixed-block model for washer disinfector, steriliser and autoclave validation | |
| PC interface and software with ramps and dwells |
Applications
| On-site calibration of temperature sensors, switches and transmitters | |
| Validation of washer disinfectors, steam sterilisers and autoclaves (HTM 2010) |
Key specifications
| Temperature range | −35 to +140 °C (Low), 30 to 350 °C (Medium), 35 to 650 °C (High) |
|---|---|
| Stability | 0.02 to 0.05 °C |
| Accuracy | ±0.15 to ±0.5 °C (Complete with semi-standard PRT); ±0.2 °C to ±2 °C (Basic) |
| Calibration volume | 25 mm Ø × 148 mm (inserts) |
| Weight | < 6.6 kg |
| Power | 150 W (Low) / 750 W (Medium, High) |
General
| Calibration capacity | HTM 2010: fixed block 8, 6.5, 3 × 4.5 mm × 145 mm; others: 25 mm Ø × 148 mm removable inserts |
|---|---|
| Standard insert | 2 × 4.5 mm + 1 × 6.5 mm × 140 mm deep (custom and blank inserts available) |
| Dimensions | 228 × 248 × 143 mm |
| Weight | 6.60 kg (Low), 6.35 kg (Medium, High) |
| Certificate | Traceable certificate included; five-point UKAS optional |
| Accuracy note | Complete-model accuracy with a suitable Isotech semi-standard PRT |
Models
| Model | Range (20 °C ambient) | Stability | Accuracy Basic | Accuracy Complete | Heating | Cooling | Power |
|---|---|---|---|---|---|---|---|
| HTM 2010 | −35 to +140 °C | 0.02 °C | ±0.2 °C | ±0.15 °C | −30 → 140 °C in 15 min | 140 → 0 °C in 15 min | 150 W |
| Low | −35 to +140 °C | 0.02 °C | ±0.2 °C | ±0.15 °C | −30 → 140 °C in 15 min | 140 → 0 °C in 15 min | 150 W |
| Medium | 30 to 350 °C | 0.03 °C | ±0.3 °C | ±0.2 °C | 50 → 350 °C in 15 min | 350 → 100 °C in 40 min | 750 W |
| High | 35 to 650 °C | 0.03–0.05 °C | ±1 °C (500 °C), ±2 °C (650 °C) | ±0.5 °C | 50 → 650 °C in 20 min | 650 → 300 °C in 20 min | 750 W |
Notes
| Data from the manufacturer's published datasheet. Confirm model, range, materials and approvals with Argonmark before ordering. |
Photo: courtesy of Isotech, used with permission (source) — background removed by Argonmark. All photo credits
Description
The Isotech Fast-Cal is a rugged, lightweight dry block calibrator range for site work, in a hygienic stainless steel case weighing under 6.6 kg. Low (−35 to +140 °C), Medium (30 to 350 °C) and High (35 to 650 °C) models reach their temperatures in 15–20 minutes with stability of 0.02–0.05 °C.
Basic versions compare the sensor to the block controller; Complete versions add a built-in indicator and semi-standard probe for traceable calibration (to ±0.15 °C), thermostat-trip capture and a 4–20 mA input. The HTM 2010 model with a fixed block is made for steriliser and autoclave validation.
Argonmark Ltd supplies Isotech instruments across Bangladesh — Dhaka, Chattogram, Gazipur, Narayanganj and the gas fields, refineries, terminals and power plants beyond. Send us the model, range, process connection, output and any hazardous-area requirement, and we will confirm the right configuration, lead time and price.