Blancett B3000 flow monitor (rate / total), battery, loop or solar, explosion-proof option
Pricing depends on specification, quantity and delivery location. Send your requirement and we reply with a costed quotation within 24 hours.
Quick overview
- Type: Flow
- Signal / Protocol: 4–20 mA, Modbus, Pulse / frequency
- Hazardous area: Hazardous-area rated / option
- Genuine productsSourced from the manufacturer or authorised channels
- Delivery across BangladeshDhaka, Chattogram and all industrial zones
- After-sales supportInstallation guidance and warranty handling
- Reply within 24 hoursCall +880 1713 552466 or email hello@argonmark.com
Specifications
| General | |
|---|---|
| Part no. | BD-1449 |
| Category | Oil & Gas Instruments |
| Group | Instrumentation & Control |
| Brand | Blancett |
| Model | B3000 (B30B/A/S/X/Z) |
| Technical | |
| Type | Flow |
| Signal / Protocol | 4–20 mA, Modbus, Pulse / frequency |
| Hazardous area | Hazardous-area rated / option |
Datasheet
Technical features
| Base, Advanced (Modbus + alarms) and Solar versions | |
| Polycarbonate NEMA 4X or copper-free aluminium explosion-proof enclosure | |
| Solar, battery and 4–20 mA loop power | keeps readings and settings through power loss |
|---|---|
| Simultaneous rate and total; batch and grand totals | |
| Field-programmable units and time base | |
Applications
| Oil field injection, fracturing and remediation metering | |
| Chemical batching and remote sites without mains power |
Power and approvals
| Battery | 3.6 V lithium D cell, up to 6 years (B30A/B/X/Z) |
|---|---|
| Loop | 4–20 mA, 7 V loop loss |
| Solar (B30S) | Integrated PV cell; NiCd battery gives up to 30 days after 6–8 h sun |
| Intrinsically safe (B30A/B/S) | Class I Div 1 Groups C, D; Class II Div 1 E, F, G; Class III (UL 913, CSA C22.2 No. 157) |
| Explosion-proof (B30X/Z) | Class I Div 1 Groups B, C, D; ATEX II 2 G Ex d IIC T4 Gb, II D Ex tb IIIC T135 °C Db |
Key specifications
| Input | Magnetic pickup 1–3,500 Hz (turbine sensors) or amplified pulse |
|---|---|
| Display | 6-digit rate + 7-digit total, simultaneous |
| Accuracy | 0.05% (frequency measurement ±0.1%) |
| Output | 4–20 mA, totalizing pulse; alarms and Modbus RTU on Advanced models |
| Power | Lithium D cell (up to 6 years), 4–20 mA loop, or solar |
| Approvals | IS Class I Div 1; explosion-proof Class I Div 1 and ATEX Ex d IIC (B30X/Z) |
Inputs
| Frequency range | 1 to 3,500 Hz |
|---|---|
| Frequency measurement accuracy | ±0.1% |
| Trigger sensitivity | 30 or 60 mVp-p, jumper selected |
| Over-voltage protection | 28 V DC |
Outputs and communication
| Analog | 4–20 mA two-wire loop, 25 mA limit |
|---|---|
| Totalizing pulse | One pulse per LSD increment; 28 V DC, 100 mA, max. 16 Hz, 30 ms |
| Status alarms (B30A/Z) | Two open-collector outputs, adjustable with dead band |
| Modbus (B30A/Z) | Modbus RTU over RS485, 127 units, 9,600 baud |
General
| Accuracy | 0.05% |
|---|---|
| Response | 1 to 100 s adjustable damping |
| Environment | −30 to +70 °C; 0–90% RH non-condensing |
| Enclosure | Polycarbonate NEMA 4X/IP66, or copper-free epoxy-coated aluminium NEMA 4X/IP66 |
| Units | Liquid and gas volume units; K-factor in pulses per gallon, m³, litre or ft³ |
Notes
| Data from the manufacturer's published datasheet. Confirm model, range, materials and approvals with Argonmark before ordering. |
Photo: courtesy of Blancett, used with permission (source) — background removed by Argonmark. All photo credits
Description
The Blancett B3000 is a flow rate indicator and totalizer for turbine flow sensors, reading 1 to 3,500 Hz pickup signals and showing rate and total together with 0.05% accuracy. The Base model covers standard metering, the Advanced adds two alarms and Modbus RTU, and the Solar model runs from an integrated photovoltaic cell.
It can be powered by a six-year lithium battery or the 4–20 mA loop, and comes in a NEMA 4X polycarbonate housing (intrinsically safe) or an aluminium explosion-proof housing with ATEX Ex d approval.
Argonmark Ltd supplies Blancett instruments across Bangladesh — Dhaka, Chattogram, Gazipur, Narayanganj and the gas fields, refineries, terminals and power plants beyond. Send us the model, range, process connection, output and any hazardous-area requirement, and we will confirm the right configuration, lead time and price.
Questions & answers
Customer questions
No questions asked yet. Ask about specification, compatibility, lead time or anything else about this item.