Laurel Laureate RTD temperature panel meter / controller, Pt100, Ni120, Cu10, 2/3/4-wire
Pricing depends on specification, quantity and delivery location. Send your requirement and we reply with a costed quotation within 24 hours.
Quick overview
- Type: Temperature
- Signal / Protocol: Relay / switch
- Hazardous area: General purpose
- Genuine productsSourced from the manufacturer or authorised channels
- Delivery across BangladeshDhaka, Chattogram and all industrial zones
- After-sales supportInstallation guidance and warranty handling
- Reply within 24 hoursCall +880 1713 552466 or email hello@argonmark.com
Specifications
| General | |
|---|---|
| Part no. | BD-1497 |
| Category | Oil & Gas Instruments |
| Group | Instrumentation & Control |
| Brand | Laurel Electronics |
| Model | Laureate RTD |
| Technical | |
| Type | Temperature |
| Signal / Protocol | Relay / switch |
| Hazardous area | General purpose |
Datasheet
Technical features
| Factory calibrated for four RTD types; calibration stored on the signal board so boards and sensors can be swapped without recalibration | |
| Automatic lead-resistance compensation for 3- and 4-wire; measured and subtracted for 2-wire | |
| Up to 60 conversions per second; peak or valley display | |
| Adaptive digital filtering with 8 time constants (80 ms to 9.6 s) or auto mode | |
| Optional relays (alarm/control), isolated analog output and serial/Ethernet communication |
Applications
| Process temperature display and alarms on panels | |
| Temperature control with relay outputs | |
| Retransmission of RTD temperature as 4–20 mA |
Key specifications
| Input | Pt100 (DIN 0.00385 or ANSI 0.003902), Ni120, Cu10 RTD; 2, 3 or 4-wire |
|---|---|
| Range | −200 to +850 °C (Pt100) |
| Accuracy | ±0.01% of span + conformity error (±0.03 °C Pt100 DIN) |
| Resolution | 1°, 0.1° or 0.01°; °C, °F, K or °R |
| Power | 85–264 V AC (10–48 V DC / 12–32 V AC option) |
| Case | 1/8 DIN, NEMA 4X front |
Measurement
| Overall accuracy at 25 °C | ±0.01% of full span + conformity error |
|---|---|
| Span tempco | ±0.003% of reading/°C |
| Calibration standards | Pt100 DIN per IEC 751 (ITS-90); Pt100 ANSI per NIST Monograph 126; Ni120 per DIN 43760 |
| Lead resistance effect | 2-wire 10 mdeg/Ω up to 10 Ω; 3/4-wire 10 mdeg/Ω up to 100 Ω |
| Overvoltage protection | 125 V AC |
| Open sensor | Display flashes full scale |
| A-to-D | Concurrent Slope; 60/s (60 Hz); display update 3.5/s |
| Display | 5-digit LED, 14.2 mm, red or green |
General
| Power | 85–264 V AC or 90–300 V DC standard; 12–32 V AC or 10–48 V DC optional; isolation 2.3 kV |
|---|---|
| Analog output (option) | Isolated 4–20 mA, 0–20 mA, 0–10 V or ±10 V; 16-bit; compliance 12 V at 20 mA |
| Relay outputs (option) | 2 Form C or 4 Form A contact relays, 8 A at 250 V AC / 24 V DC; or 2/4 solid state relays, 120 mA at 140 V AC |
| Serial I/O (option) | Ethernet, Ethernet-to-RS485, USB, USB-to-RS485, RS485, RS485 Modbus, RS232; Modbus RTU/ASCII, Laurel ASCII; 300–19,200 baud |
| Operating / storage temperature | 0 to 55 °C / −40 to +85 °C; 95% RH at 40 °C non-condensing |
| Case | 1/8 DIN, NEMA 4X (IP65) front when panel mounted; screw-clamp plugs |
RTD types
| RTD | Alpha | Range | Excitation | Conformity error |
|---|---|---|---|---|
| Pt100 (DIN) | 0.003850 | −200 to +850 °C | 196 µA | ±0.03 °C |
| Pt100 (ANSI) | 0.003902 | −200 to +850 °C | 196 µA | ±0.04 °C |
| Ni120 | 0.00672 | −80 to +260 °C | 196 µA | ±0.05 °C |
| Cu10 | 0.00427 | −97 to +260 °C | 5.0 mA | ±0.05 °C |
Notes
| Data from the manufacturer's published datasheet. Confirm model, range, materials and approvals with Argonmark before ordering. |
Description
The Laurel Laureate RTD meter is a 1/8 DIN temperature panel meter and controller, factory calibrated for Pt100 (DIN and ANSI), Ni120 and Cu10 sensors. It reads the full range of each sensor (−200 to +850 °C for Pt100) with ±0.01% of span accuracy plus conformity error, at selectable 1°, 0.1° or 0.01° resolution in °C, °F, K or °R.
2-, 3- and 4-wire connections are supported with lead-resistance compensation, and adaptive filtering steadies readings in noisy plants. Options include alarm/control relays, an isolated 4–20 mA or 0–10 V output and Ethernet, USB or RS485 Modbus communication.
Argonmark Ltd supplies Laurel Electronics instruments across Bangladesh — Dhaka, Chattogram, Gazipur, Narayanganj and the gas fields, refineries, terminals and power plants beyond. Send us the model, range, process connection, output and any hazardous-area requirement, and we will confirm the right configuration, lead time and price.
Questions & answers
Customer questions
No questions asked yet. Ask about specification, compatibility, lead time or anything else about this item.
Reviews
No reviews yet. Bought or used this item? Be the first to share your experience.