Edgetech RH CAL portable relative humidity calibrator, chilled-mirror reference, 5–95% RH ±0.5%, 10–50 °C ±0.1 °C
Pricing depends on specification, quantity and delivery location. Send your requirement and we reply with a costed quotation within 24 hours.
Quick overview
- Type: Humidity calibrator
- Hazardous area: General purpose
- Genuine productsSourced from the manufacturer or authorised channels
- Delivery across BangladeshDhaka, Chattogram and all industrial zones
- After-sales supportInstallation guidance and warranty handling
- Reply within 24 hoursCall +880 1713 552466 or email hello@argonmark.com
Specifications
| General | |
|---|---|
| Part no. | BD-1620 |
| Category | Pressure, Temperature & Calibration |
| Group | Instrumentation & Control |
| Brand | Edgetech Instruments |
| Model | RH CAL |
| Technical | |
| Type | Humidity calibrator |
| Hazardous area | General purpose |
Datasheet
Technical features
| Completely self-contained | no compressed air or water connection needed |
|---|---|
| Primary-method chilled-mirror dew/frost point sensor for traceability and feedback control | |
| Temperature and relative humidity controlled independently | |
| Automatic Balance Control corrects for mirror contamination | |
| Probe ports for 10, 12, 18 mm, ½ and ¾ in RH probes and ½–1¼ in dew-point probes | |
| Delivered with an accredited multi-point calibration certificate | |
Applications
| On-site calibration of relative humidity transmitters and probes | |
| Validation of dew/frost point and temperature sensors | |
| Metrology laboratories, pharmaceutical and HVAC validation |
Key specifications
| RH range / accuracy | 5–95% RH, ±0.5% RH |
|---|---|
| Temperature range / accuracy | 10 to 50 °C, ±0.1 °C |
| Dew/frost point | −40 to 60 °C, ±0.2 °C nominal (D2 chilled-mirror sensor) |
| Power | 100–240 V AC, 50–60 Hz, 150 W max. |
| Weight | 15.4 kg |
| Certificate | Multi-point ISO/IEC 17025 accredited, NIST traceable |
Measurement & accuracy
| Relative humidity | 5 to 95%, ±0.5% |
|---|---|
| Temperature | 10 to 50 °C, ±0.1 °C |
| Dew/frost point | −40 to 60 °C with D2 sensor, ±0.2 °C nominal |
| Repeatability | ±0.05 °C |
| Hysteresis | Negligible |
| Mirror depression | 60 °C nominal (D2 sensor) |
| Slew rate | 1.0 °C/s max. above 0 °C |
System
| Mirror temperature sensor | 3-wire PRT, 100 Ω at 0 °C |
|---|---|
| Sample flow | 1 l/min nominal |
| Probe ports | RH probes: 10, 12, 18 mm, ½, ¾ in; dew-point probes ½ to 1¼ in; custom on request |
| Power | 100–240 V AC, 50–60 Hz, 150 W max. |
| Dimensions | 524 × 437 × 217 mm |
| Weight | 15.4 kg |
Notes
| Data from the manufacturer's published datasheet. Confirm model, range, materials and approvals with Argonmark before ordering. |
Description
The Edgetech RH CAL is a portable, self-contained humidity calibration system for the laboratory or on-site work. It generates relative humidity from 5 to 95% (±0.5%) and temperature from 10 to 50 °C (±0.1 °C), controlled independently, and needs no compressed air or water supply.
A primary-method D2 chilled-mirror sensor in the sample chamber measures dew/frost point from −40 to 60 °C for traceability and closed-loop control, with Automatic Balance Control to correct for mirror contamination. Standard probe ports accept common RH and dew-point probes, and each unit is delivered with a multi-point ISO/IEC 17025 accredited, NIST-traceable certificate.
Argonmark Ltd supplies Edgetech Instruments instruments across Bangladesh — to pulp and paper mills, water and effluent treatment plants, chemical, textile, food and power plants in Dhaka, Chattogram, Gazipur, Narayanganj and beyond. Send us the model, measuring range, process connection, wetted materials and output you need, and we will confirm the right configuration, lead time and price.
Questions & answers
Customer questions
No questions asked yet. Ask about specification, compatibility, lead time or anything else about this item.
Reviews