Specifications
| General | |
|---|---|
| Part no. | BD-1626 |
| Category | Liquid Analysis (pH, ORP & Conductivity) |
| Group | Instrumentation & Control |
| Brand | AquaMetrix |
| Model | 60 Series (P60R8, P/R60R5, P/R60C-6/-7) |
| Technical | |
| Type | pH / ORP sensor |
| Signal / Protocol | 4–20 mA |
| Hazardous area | General purpose |
Datasheet
Technical features
| True differential measurement with two glass electrodes and a metal ground electrode: virtually no ground-loop problems | |
| Replaceable double-junction salt bridge | rejuvenate the sensor at low cost |
|---|---|
| Encapsulated preamplifier transmits over inexpensive cable | |
| Fast automatic temperature compensation (Pt1000 or thermistor at the tip) | |
| P/R60C-6 | adjustable insertion 7/8–5 in in a 1¼ in NPT tee; P/R60C-7: hot-tap with ball valve |
| Flat, hard-glass and antimony electrode options (P60R8) | |
Applications
| Industrial and municipal water and wastewater treatment, neutralisation | |
| Fume scrubbers, plating and circuit-board manufacturing | |
| Pulp & paper, mining, chemical processing, food & beverage |
P/R60C-6 and -7 (1¼ in NPT, variable insertion / hot tap)
| Range | 0–14 pH; ORP −2000 to +2000 mV |
|---|---|
| Sensitivity / stability | 0.01 pH, 0.03 pH/day; 0.1 mV, 2 mV/day |
| Wetted materials | CPVC, Kynar, glass, titanium-palladium, EPDM (platinum for ORP; gold option) |
| Temperature | −5 to 95 °C (limited by pressure in flow-through use) |
| Pressure | 100 psig at 65 °C |
| Insertion depth | Adjustable 7/8 to 5 in |
| Transmission | 3000 ft (900 m) |
Key specifications
| Measuring range | 0–14 pH; ORP ±1000 mV (R60R5) or ±2000 mV (R60C) |
|---|---|
| Accuracy | ±0.02 pH (P60R8, P60R5); ORP ±5 mV |
| Process temperature | −5 to 95 °C |
| Process pressure | Max. 100 psig at 65 °C |
| Body | Ryton/PPS (R8, R5) or CPVC (C-6/-7) |
| Signal | Encapsulated preamp, up to 3000 ft (R8, C) / 2000 ft (R5); 4–20 mA P65 versions |
P60R8 (1½ in NPT body)
| Range | 0–14 pH |
|---|---|
| Accuracy / sensitivity | ±0.02 pH / 0.001 pH |
| Stability | 0.03 pH per day, non-cumulative |
| Wetted materials | Ryton, Kynar, glass, titanium-palladium, Viton |
| Temperature | −5 to 95 °C |
| Pressure | 100 psig at 65 °C |
| Max. flow | 3 m/s |
| Temperature compensation | Pt1000 RTD (300 Ω NTC option) |
| Cable | 5-conductor shielded, 4.6 m |
P60R5 / R60R5 (1 in NPT, flow-through or submersion)
| Range | 0–14 pH; ORP −1000 to +1000 mV |
|---|---|
| Accuracy | ±0.02 pH; ±5 mV |
| Stability | 0.03 pH or 2.0 mV per day |
| Wetted materials | Ryton (PPS) body, ceramic junction, glass, Viton, titanium (platinum for ORP) |
| Temperature | −5 to 95 °C at atmospheric pressure |
| Pressure | 100 psig at 65 °C |
| Temperature compensation | 300 Ω thermistor (60-series); 10 kΩ (65-series) |
| Transmission | 2000 ft (60-series); 4–20 mA (65-series) |
Notes
| Data from the manufacturer's published datasheet. Confirm model, range, materials and approvals with Argonmark before ordering. |
Description
The AquaMetrix 60 Series are differential pH and ORP sensors: a process glass electrode and a reference glass electrode in pH 7 buffer are measured against a third metal electrode, which practically eliminates ground-loop problems. The internal buffer is protected by a replaceable double-junction salt bridge, so a contaminated sensor can be restored at low cost instead of being replaced.
The family includes the P60R8 (1½ in NPT, ±0.02 pH), the 1 in P/R60R5 for flow-through or submersion, and the P/R60C-6/-7 with adjustable insertion or hot-tap mounting in a 1¼ in tee. All work from −5 to 95 °C at up to 100 psig at 65 °C, with an encapsulated preamplifier for cable runs up to 3000 ft (or a blind 4–20 mA output in the P65 versions).
Argonmark Ltd supplies AquaMetrix instruments across Bangladesh — to pulp and paper mills, water and effluent treatment plants, chemical, textile, food and power plants in Dhaka, Chattogram, Gazipur, Narayanganj and beyond. Send us the model, measuring range, process connection, wetted materials and output you need, and we will confirm the right configuration, lead time and price.
Questions & answers
Customer questions
No questions asked yet. Ask about specification, compatibility, lead time or anything else about this item.
Reviews
No reviews yet. Bought or used this item? Be the first to share your experience.