Quick overview

  • Type: pH / ORP sensor
  • Signal / Protocol: 4–20 mA
  • Hazardous area: General purpose
Call +880 1713 552466
  • Genuine productsSourced from the manufacturer or authorised channels
  • Delivery across BangladeshDhaka, Chattogram and all industrial zones
  • After-sales supportInstallation guidance and warranty handling
  • Reply within 24 hoursCall +880 1713 552466 or email hello@argonmark.com

Specifications

General
Part no.BD-1626
CategoryLiquid Analysis (pH, ORP & Conductivity)
GroupInstrumentation & Control
BrandAquaMetrix
Model60 Series (P60R8, P/R60R5, P/R60C-6/-7)
Technical
TypepH / ORP sensor
Signal / Protocol4–20 mA
Hazardous areaGeneral purpose

Datasheet

AquaMetrix 60 Series (P60R8, P/R60R5, P/R60C-6/-7)

Technical features

True differential measurement with two glass electrodes and a metal ground electrode: virtually no ground-loop problems
Replaceable double-junction salt bridgerejuvenate the sensor at low cost
Encapsulated preamplifier transmits over inexpensive cable
Fast automatic temperature compensation (Pt1000 or thermistor at the tip)
P/R60C-6adjustable insertion 7/8–5 in in a 1¼ in NPT tee; P/R60C-7: hot-tap with ball valve
Flat, hard-glass and antimony electrode options (P60R8)

Applications

Industrial and municipal water and wastewater treatment, neutralisation
Fume scrubbers, plating and circuit-board manufacturing
Pulp & paper, mining, chemical processing, food & beverage

P/R60C-6 and -7 (1¼ in NPT, variable insertion / hot tap)

Range0–14 pH; ORP −2000 to +2000 mV
Sensitivity / stability0.01 pH, 0.03 pH/day; 0.1 mV, 2 mV/day
Wetted materialsCPVC, Kynar, glass, titanium-palladium, EPDM (platinum for ORP; gold option)
Temperature−5 to 95 °C (limited by pressure in flow-through use)
Pressure100 psig at 65 °C
Insertion depthAdjustable 7/8 to 5 in
Transmission3000 ft (900 m)

Key specifications

Measuring range0–14 pH; ORP ±1000 mV (R60R5) or ±2000 mV (R60C)
Accuracy±0.02 pH (P60R8, P60R5); ORP ±5 mV
Process temperature−5 to 95 °C
Process pressureMax. 100 psig at 65 °C
BodyRyton/PPS (R8, R5) or CPVC (C-6/-7)
SignalEncapsulated preamp, up to 3000 ft (R8, C) / 2000 ft (R5); 4–20 mA P65 versions

P60R8 (1½ in NPT body)

Range0–14 pH
Accuracy / sensitivity±0.02 pH / 0.001 pH
Stability0.03 pH per day, non-cumulative
Wetted materialsRyton, Kynar, glass, titanium-palladium, Viton
Temperature−5 to 95 °C
Pressure100 psig at 65 °C
Max. flow3 m/s
Temperature compensationPt1000 RTD (300 Ω NTC option)
Cable5-conductor shielded, 4.6 m

P60R5 / R60R5 (1 in NPT, flow-through or submersion)

Range0–14 pH; ORP −1000 to +1000 mV
Accuracy±0.02 pH; ±5 mV
Stability0.03 pH or 2.0 mV per day
Wetted materialsRyton (PPS) body, ceramic junction, glass, Viton, titanium (platinum for ORP)
Temperature−5 to 95 °C at atmospheric pressure
Pressure100 psig at 65 °C
Temperature compensation300 Ω thermistor (60-series); 10 kΩ (65-series)
Transmission2000 ft (60-series); 4–20 mA (65-series)

Notes

Data from the manufacturer's published datasheet. Confirm model, range, materials and approvals with Argonmark before ordering.

Description

The AquaMetrix 60 Series are differential pH and ORP sensors: a process glass electrode and a reference glass electrode in pH 7 buffer are measured against a third metal electrode, which practically eliminates ground-loop problems. The internal buffer is protected by a replaceable double-junction salt bridge, so a contaminated sensor can be restored at low cost instead of being replaced.

The family includes the P60R8 (1½ in NPT, ±0.02 pH), the 1 in P/R60R5 for flow-through or submersion, and the P/R60C-6/-7 with adjustable insertion or hot-tap mounting in a 1¼ in tee. All work from −5 to 95 °C at up to 100 psig at 65 °C, with an encapsulated preamplifier for cable runs up to 3000 ft (or a blind 4–20 mA output in the P65 versions).

Argonmark Ltd supplies AquaMetrix instruments across Bangladesh — to pulp and paper mills, water and effluent treatment plants, chemical, textile, food and power plants in Dhaka, Chattogram, Gazipur, Narayanganj and beyond. Send us the model, measuring range, process connection, wetted materials and output you need, and we will confirm the right configuration, lead time and price.

Questions & answers

Customer questions

No questions asked yet. Ask about specification, compatibility, lead time or anything else about this item.

Ask a question

Please don’t include links. Questions are published together with our answer.

Reviews

No reviews yet. Bought or used this item? Be the first to share your experience.

Write a review

Your rating

Reviews are checked before they appear.

Price on requestQuote within 24 hours

Request a quotation

AquaMetrix 60 Series differential pH/ORP sensors (P60R8, P/R60R5, P/R60C-6/-7), replaceable salt bridge, −5 to 95 °C
Part no. BD-1626 · Catalogue no. 60 Series (P60R8, P/R60R5, P/R60C-6/-7)

Opens your email app with this request filled in. We reply within 24 hours.