Instrumentation & Control

Endress+Hauser Memosens CPS76E digital pH/ORP sensor for process and H₂S media, 0–14 pH, 0–140 °C, 14 bar, Ex Zone 0

Part no.
BD-1648
Brand
Endress+Hauser
Catalogue no.
Memosens CPS76E
Available on order · sourced to your specification
Price on request

Pricing depends on specification, quantity and delivery location. Send your requirement and we reply with a costed quotation within 24 hours.

Quick overview

  • Type: pH / ORP sensor
  • Hazardous area: Hazardous-area rated / option
Call +880 1713 552466
  • Genuine productsSourced from the manufacturer or authorised channels
  • Delivery across BangladeshDhaka, Chattogram and all industrial zones
  • After-sales supportInstallation guidance and warranty handling
  • Reply within 24 hoursCall +880 1713 552466 or email hello@argonmark.com

Specifications

General
Part no.BD-1648
CategoryLiquid Analysis (pH, ORP & Conductivity)
GroupInstrumentation & Control
BrandEndress+Hauser
ModelMemosens CPS76E
Technical
TypepH / ORP sensor
Hazardous areaHazardous-area rated / option

Datasheet

Endress+Hauser Memosens CPS76E

Technical features

Simultaneous pH, ORP and rH measurement in one combined electrode
Poison-resistant reference with ion trap for media with H₂S and other electrode poisons
Glass-breakage and blockage detection (glass and reference impedance)
Memosens digital, non-contact inductive signal transfer; sensor stores calibration and operating history
Acrylamide-free, sterilisable gel; CIP/SIP capable and autoclavable
Integrated NTC 30K temperature sensor

Applications

Chemical processes with rapidly changing pH
Media with electrode poisons such as H₂S (refining, pulp & paper, wastewater)
Hygienic processes needing CIP/SIP or autoclaving

Construction

ShaftGlass to suit process
pH membrane glassType B or type N
ReferenceAg/AgCl lead with ion trap, KCl 3M gel, AgCl-free; TP version pressurised 7 bar abs with indicator
JunctionCeramic, zirconium dioxide
ORP elementPlatinum
Temperature sensorNTC 30K
Plug-in headMemosens, digital non-contact, 16 bar (rel.) pressure resistance
Process connectionPg 13.5
Degree of protectionIP68 (10 m, 25 °C, 45 days)
EMCEN 61326-1, EN 61326-2-3, NAMUR NE21

Key specifications

Measuring rangepH 0–14 (application B) or 0–12 (H); ORP −1500 to +1500 mV; rH
Process temperature0 to 140 °C
Process pressure0.8–14 bar abs (B) or 0.8–7 bar abs (H)
ReferenceAg/AgCl with ion trap, gel KCl 3M (pressurised 7 bar option)
ConnectionMemosens inductive plug-in head, Pg 13.5, IP68
ApprovalsATEX, IECEx, CSA C/US, NEPSI, Japan Ex, INMETRO (Zone 0/1/2)

Measurement

pH, application B0–14 pH, 0 to 140 °C
pH, application H0–12 pH, 0 to 140 °C
ORP−1500 to +1500 mV
Other valuesrH (calculated), temperature
Minimum conductivity10 µS/cm (atmospheric pressure, no flow)

Process conditions

Process temperature0 to 140 °C; pressurised-reference versions max. 100 °C continuous (140 °C for sterilisation)
Process pressure, application B0.8 to 14 bar absolute
Process pressure, application H0.8 to 7 bar absolute

Approvals & system

Hazardous areasATEX, IECEx, CSA C/US, NEPSI, Japan Ex, INMETRO for Zone 0, 1 and 2
TransmittersLiquiline CM44, CM42 (two-wire for hazardous areas) and other Memosens transmitters
CableMemosens CYK10 or CYK20
Assembliese.g. Dipfit CPA111 immersion, Flowfit CPA250 flow

Notes

Data from the manufacturer's published datasheet. Confirm model, range, materials and approvals with Argonmark before ordering.

Description

The Endress+Hauser Memosens CPS76E is a combined digital electrode that measures pH, ORP and rH at the same time. Its poison-resistant reference with an ion trap and acrylamide-free gel electrolyte is designed for chemical processes with rapidly changing pH and media containing electrode poisons such as H₂S, and it is CIP/SIP capable and autoclavable.

It covers 0–14 pH and ±1500 mV from 0 to 140 °C at up to 14 bar absolute. Memosens technology transmits the signal digitally and contact-free, stores calibration and operating history in the sensor head, and detects glass breakage and reference blockage. It carries ATEX, IECEx, CSA and other approvals for Zone 0, 1 and 2.

Argonmark Ltd supplies Endress+Hauser instruments across Bangladesh — to pulp and paper mills, water and effluent treatment plants, chemical, textile, food and power plants in Dhaka, Chattogram, Gazipur, Narayanganj and beyond. Send us the model, measuring range, process connection, wetted materials and output you need, and we will confirm the right configuration, lead time and price.

Questions & answers

Customer questions

No questions asked yet. Ask about specification, compatibility, lead time or anything else about this item.

Ask a question

Please don’t include links. Questions are published together with our answer.

Reviews

No reviews yet. Bought or used this item? Be the first to share your experience.

Write a review

Your rating

Reviews are checked before they appear.

Price on requestQuote within 24 hours

Request a quotation

Endress+Hauser Memosens CPS76E digital pH/ORP sensor for process and H₂S media, 0–14 pH, 0–140 °C, 14 bar, Ex Zone 0
Part no. BD-1648 · Catalogue no. Memosens CPS76E

Opens your email app with this request filled in. We reply within 24 hours.