WIKA CPP120-X pneumatic comparison test pump, 0–120 bar

WIKA CPP30 pneumatic hand test pump, −0.95 to +35 bar

WIKA CPP4000-X hydraulic comparison test pump, 0–4000 bar

WIKA CPP7000-X hydraulic comparison test pump, 0–7000 bar

WIKA CPB3800HP high-pressure dead-weight tester, up to 2,600 bar

WIKA CPB5000HP high-pressure pressure balance, up to 5,000 bar

Edgetech DewMaster chilled-mirror dew/frost point hygrometer, −90 to +95 °C dp

Armstrong VERIS Accelabar flow meter (venturi + averaging pitot), 1–12 in, Class 150–600

Blancett B3000 flow monitor (rate / total), battery, loop or solar, explosion-proof option

Keller Acculevel high-accuracy submersible level transmitter, 4–20 mA or 0–5/10 V + RS485, NSF 61

Keller LevelRat non-fouling submersible level transmitter for wastewater, intrinsically safe option
Keller Levelgage general-purpose submersible level transmitter, intrinsically safe, NSF 61
Keller Microlevel 16 mm (0.63 in) submersible level transmitter, 4–20 mA + RS485, NSF 61

Keller Nanolevel ceramic submersible level transmitter for very low ranges, 0–100 mm to 0–3 m water

Druck DPI620G Genii modular multifunction calibrator and HART/Fieldbus communicator, intrinsically safe option

Dwyer SPPM smart programmable panel meter, colour touch screen, 0–40 V DC or 0–50 mA input

NOSHOK 1900C loop-powered 3½-digit digital indicator, 4–20 mA or 10–50 mA, DIN panel mount

NOSHOK 2200 Series dual-display universal digital indicator, mA / V / thermocouple / RTD input

NOSHOK 1950 compact 5-digit smart digital indicator, current / voltage / resistance input

Isotech milliK precision thermometer, SPRT / PRT / thermistor / thermocouple / 4–20 mA, −270 to 1,820 °C

WIKA CTH7000 two-channel hand-held precision thermometer, Pt100 / thermistor, 0.015 K, −200 to 962 °C

Druck DPI 104 pressure calibration kit: 0.05% digital test gauge with pneumatic or hydraulic hand pump

Druck DPI 611 hand-held pressure calibrator, built-in pump 95% vacuum to 20 bar, 0.0185% FS

Dwyer Digihelic II differential pressure controller, 2 relays, 4–20 mA, Modbus, NEMA 4 housing

APG PG10 digital pressure gauge with 5.5 in display, bar graph and data logging, to 690 bar

APG PG5 general-purpose digital pressure gauge, vacuum to 690 bar, ±0.25% FS

APG PG7 sealed digital pressure gauge, vacuum to 2,070 bar, IP67, optional relays and Modbus

Druck DPI 104 digital test gauge, 0.05% FS, 0.7 to 1,400 bar, intrinsically safe option

Keller ECO 2 compact digital pressure gauge, −1…30 bar or 0…300 bar, max/min, intrinsically safe option

Keller LEO-Record digital pressure gauge with data logger, −1…3 to 0…1,000 bar, 0.05% FS

Keller LEO1 digital pressure gauge with fast peak detection (≥ 1 kHz), −1…3 to 0…1,000 bar, 0.1% FS

Keller LEO2 compact digital pressure gauge, 0…4 to 0…700 bar abs., 0.1% FS, intrinsically safe option

Keller LEO 3 loop-powered pressure transmitter with digital display, 4–20 mA + RS485, −1…3 to 0…1,000 bar

Keller LEO5 high-resolution digital manometer, 0.05% FS, data logger, 1 kHz peak, stainless steel, −1…1 to 0…1,000 bar

Keller LEX1 digital precision pressure gauge, 0.05% FS total error band (to 0.01% FS), RS485, −1…1 to 0…1,000 bar

WIKA CPG1500 precision digital pressure gauge, to 0.025% FS, up to 10,000 bar, data logger, Bluetooth, intrinsically safe

Mensor CPG2300 portable digital pressure gauge, single or dual sensor, 0.015% FS, optional 4–20 mA

Druck UNIK 5000 configurable pressure sensor / transmitter, 70 mbar to 700 bar, to ±0.04% FS, mV / mA / V outputs

Dwyer ISDP intrinsically safe differential pressure transmitter, 0.25 to 100 in w.c., 4–20 mA, LCD

Keller 23 Ed / 25 Ed flameproof pressure transmitters, Ex db IIC, −1 to 300 bar, 4–20 mA or 0–10 V

Keller 33 X Ed / 35 X Ed digital flameproof pressure transmitters, Ex db IIC, 0.05% error band, RS485 + 4–20 mA

Keller 35 X HT / HTT pressure transmitters for bio-reactors and autoclaves, compensated to 150 °C, −1 to 30 bar

Keller 35 X HTC high-temperature pressure transmitter, media to 300 °C, 3 to 1,000 bar, flush diaphragm

Keller Preciseline high-precision digital pressure transmitter, 0.1% FS, 4–20 mA / 0–10 V + RS485, to 1,000 bar
Keller Valueline high-accuracy pressure transmitter, 0.1% FS, intrinsically safe 4–20 mA option, to 1,000 bar

Mercoid MPC Jr ¼ DIN level / pump controller, one or two pumps with alternation, 4–20 mA input, 24 V loop supply

Mercoid MPC ¼ DIN pump controller with alternation, seal-failure and over-temperature monitoring, 4–20 mA input

King Instrument 7100 all-316L stainless steel low-flow rotameter, 2.4–95 L/h water, up to 276 bar

King Instrument 7710 stainless steel metal-tube rotameter, 33 GPH to 450 GPM water, 4–100 SCFM air, optional 4–20 mA

NOSHOK 820 / 821 digital temperature indicator-transmitter, Pt100 Class A, 4-digit LED, 4–20 mA, 316 SS

WIKA CTH63I0 intrinsically safe hand-held digital thermometer, Pt100, 0.1 K, Ex ib IIB T4

Dynasonics DFX clamp-on Doppler ultrasonic flow meter for slurries and aerated liquids, pipes from 6 mm

Endress+Hauser Proline Prosonic Flow P 500 clamp-on ultrasonic flow meter, DN15 to DN4000, −40 to 170 °C, up to 3 I/Os

Bently Nevada 2300 series vibration monitor, 2 channels + speed, relays, 4–20 mA (2300/20) or System 1 (2300/25)

Portable shaker table 9100D for field checking accelerometers, velocity sensors and proximity probes, 7 Hz–10 kHz

Endress+Hauser Memosens CPS91E digital pH sensor for heavily polluted media, open aperture, 0–14 pH, Ex ia

Rosemount 1056 dual-channel liquid analysis transmitter, pH/ORP, conductivity, chlorine, DO, ozone, turbidity, HART or Profibus DP



GF Signet 2724–2726 general-purpose pH/ORP electrode, PPS body, ¾ in NPT, DryLoc connector, 0–85 °C, 6.8 bar

Rosemount 400 / 400VP Endurance screw-in contacting conductivity sensor, cell constant 0.01/0.1/1.0, ¾ in MNPT, to 105 °C (200 °C option)

GF Signet 2850 conductivity/resistivity sensor electronics and integral systems, 0.055–400,000 µS, 4–20 mA or digital S3L

Rosemount TUpH 396P / 396PVP pH/ORP sensor, polypropylene body, 1 in MNPT, 0–14 pH or ±1500 mV, SMART preamplifier

Dwyer 626 / 628 industrial pressure transmitter, 316L SS, 0–5 to 0–8000 psi, 4–20 mA or voltage, 0.25% / 1% FS, NEMA 4X

Rosemount 1066 loop-powered single-channel liquid analysis transmitter, pH/ORP, conductivity, chlorine, DO, ozone, HART or FOUNDATION Fieldbus, IS

Rosemount 228 toroidal (inductive) conductivity sensor, PEEK or Tefzel, up to 200 °C, 295 psig, up to 2,000,000 µS/cm


Edgetech RH CAL portable relative humidity calibrator, chilled-mirror reference, 5–95% RH ±0.5%, 10–50 °C ±0.1 °C

Rosemount 389 / 389VP general-purpose pH/ORP sensor, Tefzel body, triple-junction reference, 0–85 °C, 1 in MNPT

GF Type 546 true-union ball valve, ⅜–4 in, PVC / CPVC / PP / ABS / PVDF, PTFE seats, EPDM or FPM seals

Rosemount TUpH 396R / 396RVP retractable pH/ORP sensor, titanium tube 533 or 914 mm, hot-tap via ball valve, 0–100 °C



AquaMetrix 60 Series differential pH/ORP sensors (P60R8, P/R60R5, P/R60C-6/-7), replaceable salt bridge, −5 to 95 °C

Rosemount PERpH-X 3500P / 3500VP pH/ORP sensor, rebuildable reference, 5–120 °C, 6.9 barg, 1 in MNPT

Rosemount PERpH-X 3300HT / 3300HTVP high-temperature pH/ORP sensor, up to 155 °C, 400 psig, titanium/Ryton




Rosemount 402 / 402VP retractable contacting conductivity sensor, removable through 1¼ in ball valve, 0–100 °C, 200 psig

Rosemount 403 / 403VP sanitary-flange conductivity sensor for WFI and food & beverage, 1½ or 2 in, steam sterilisable to 135 °C

Rosemount 1057 three-channel liquid analysis transmitter, pH/ORP/ISE and contacting conductivity, four 0/4–20 mA outputs, alarm relays



Rosemount PERpH-X 3400HT / 3400HTVP retractable high-temperature pH/ORP sensor, up to 155 °C, 21 or 36 in titanium


Rosemount 372 HF-resistant pH sensor for fluoride and hydrofluoric acid, 0–12 pH, Ultem body, −5 to 50 °C

Rosemount TUpH 396 / 396VP pH sensor for dirty and abrasive processes, 0–14 pH, 0–100 °C, 10.3 barg, 316 SS body

Dwyer WMT2 multi-jet water meter with pulse output, ½–2 in, up to 160 GPM / 30 m³/h, brass, 16 bar


WIKA CTH6300 hand-held digital thermometer, 1 or 2 channels, Pt100 (0.1 K) and thermocouples, −200 to 1500 °C

Dwyer DPG Series digital pressure gauge, ±0.25% or ±0.5% FS, vacuum to 5000 psi, battery powered, FM IS option

Rosemount 242 flow-through toroidal conductivity sensor, 1–4 in (DN25–DN100), PEEK/Teflon/alumina liner, ANSI or DIN flanges

Rosemount 226 large-bore toroidal conductivity sensor, glass-filled PEEK, 120 °C, 295 psig, for high suspended solids

Rosemount 404 Endurance low-flow conductivity sensor with integral flow cell, cell constant 0.01/0.1, PVC or stainless steel

Endress+Hauser Memosens CPS76E digital pH/ORP sensor for process and H₂S media, 0–14 pH, 0–140 °C, 14 bar, Ex Zone 0

APG DCR-1006A programmable level controller for MNU/DST ultrasonic sensors and MPX probe, 4 relays, 4–20 mA, Modbus


Rosemount 222 flow-through toroidal conductivity sensor, Teflon-lined, 1 or 2 in ANSI flanges, up to 182 °C, to 2 S/cm

Dwyer DPGA / DPGW economical digital pressure gauges, ±1% FS, vacuum to 500 psi, selectable units, air or liquids

AquaMetrix AM-ES1 wide-range toroidal (electrodeless) conductivity sensor, 4–400,000 µS/cm, polypropylene, Pt1000
Pulp & paper instruments: buying guide and questions
How to choose a pulp and paper instrument
- Stock and slurry flow
- Use electromagnetic flow meters with abrasion-resistant liners for pulp stock, filler slurries and white water; slurry-duty meters handle high consistency.
- Chemistry
- pH/ORP sensors with coating-resistant references for headbox, bleaching and effluent; toroidal conductivity sensors for liquors and caustic concentration.
- Pressure and level
- Pressure transmitters and submersible level sensors for chests, tanks, steam and hydraulic systems; flush diaphragms for fibrous media.
- Steam and utilities
- Temperature sensors and transmitters, dew-point and humidity instruments for dryers and compressed air.
- Maintenance
- Calibrators, test pumps and precision thermometers keep the mill's instruments accurate.
Which flow meter is best for pulp stock?
An electromagnetic flow meter: it has no moving parts or obstruction and is not affected by fibre. Choose a liner and electrodes suitable for the consistency and chemicals.
How do I keep pH sensors working in a paper mill?
Choose sensors with poisoning-resistant or rebuildable references and flat glass, mount them where they stay wet and clean, and calibrate regularly; retractable sensors allow cleaning without shutdown.
Do you supply complete instrument packages for paper mills in Bangladesh?
Yes. Send the instrument list or P&ID and we quote suitable models from Rosemount, Keller, WIKA, Endress+Hauser, Dwyer, Druck, NOSHOK and APG and other makes within 24 hours.